Age | Commit message (Collapse) | Author |
|
Sometimes the preferred mode is not available due to hardware
constraints (e.g. GPU or cable bandwidth limitations). In these
cases it's better to fallback to lower modes than to end up with
a black screen.
|
|
When a layer surface shrinks we need to damage the area it previously
occupied, but we don't know the location of all its subsurfaces in the
previous state, so instead damage a rectangle that encloses the entire
previous extent.
|
|
The xdg-decoration protocol allows clients to request whether they want
to use server side decorations or client side decorations. Currently,
sway ignores this and always enforces whatever the server is currently
set to. Although tiled clients cannot be allowed to set borders, there
is no harm in listening requests from floating clients. Sidenote: also
fix an unrelated style error.
|
|
|
|
|
|
Losing the precision resulted in wlr_cursor and wlr_seat::pointer_state
getting out of sync during pointer motion in seatop_down.
Since the difference was always under 1 px, it was practically
impossible to notice in normal use.
But because of being out of sync, cursor_rebase would always end up
incorrectly calling wlr_seat_pointer_notify_motion from
seatop_default_begin (on releasing mouse button) which broke cursor
locking.
See #5405
Closes #4632
|
|
The old URL gives a 404.
|
|
|
|
|
|
|
|
When emulating touch, the simulating_pointer_from_touch field is
set to true. It's switched back to false when a touch_up event is
received. However we need to ensure we always send a wl_pointer.frame
event following a group of other wl_pointer events.
Since a touch_frame event is always guaranteed to come after a group
of touch events, unset simulating_pointer_from_touch in the touch_frame
handler instead of the touch_up handler. Add a new field to know whether
the touch_frame handler should stop emulation.
|
|
If HOME environment variable is not set, sway fails startup with a
segmentation fault due to null pointer dereference.
Also check calloc return value and only perform the fallback code when
really needed.
Signed-off-by: Tobias Stoeckmann <tobias@stoeckmann.org>
|
|
Add a subcommand for `gaps` that allows to toggle gaps at
runtime. This functionality is part of i3-gaps since [1]
but is missing in sway.
[1] https://github.com/Airblader/i3/pull/264
|
|
|
|
Whenever the selection is cancelled by the user, exit 1, since not
screenshot has been taken.
|
|
Update for the breaking change in [1].
[1]: https://github.com/swaywm/wlroots/pull/3001
|
|
Update for the breaking change in [1].
[1]: https://github.com/swaywm/wlroots/pull/3011
|
|
When setting the geometry from content for floating windows, the
coordinates for borders are normally taken into account. However in the
case of a floating fullscreen window, we should not be doing this. Since
the content of the container takes the space of the entire output, this
causes the calculated borders to neccesarily be outside of the output.
This later causes a problem when sending surface entrance events since
in a multi-monitor setup, the border coordinates will overlap with
another output despite the surface not actually being on that output at
all. The fix is to just ignore border coordinates for a floating
fullscreen container since fullscreen, of course, does not actually have
any borders. Fixes #6080.
|
|
|
|
Danish is the only language in the README that is not named in its own language.
<sorry for the frivolity but the inconsistency bugs me>
|
|
New warnings can be hard to notice in CI, since CI will just pass in
that case. Meson sometimes uses warnings for important mistakes, e.g.
invalid option.
Let's turn warnings into errors so that we can spot these more easily.
|
|
ExternalProgram.path has been deprecated.
|
|
Dependency.get_pkgconfig_variable has been deprecated.
|
|
meson.build_root() is deprecated.
References: https://github.com/mesonbuild/meson/pull/8629
|
|
This isn't used anymore.
|
|
|
|
|
|
get_current_time_msec is only used in cursor.c, so we can move it in and
make it static. This is primarily intended to avoid a symbol collision
with wlroots, which we unfortunately do not have a good solution for
yet.
|
|
|
|
This reverts commit 487c83f0de9ca2a7650ad636eed6fd694ddcb82e.
The --create flag is undocumented, not in i3, and at least partially
broken (#5913), so this removes the feature.
|
|
This fixes the following scenario:
- Place a floating window so its border is right at the edge of the
screen
- Create a new split
- The border disappears
- Moving the window does not restore the border
|
|
Instead of disabling it for some workspace subcommands, this explicitly
calls it only in the 2 places it's actually needed: for switching to a
named or numbered workspace.
|
|
This extracts the code to a separate workspace_auto_back_and_forth
function.
It also removes the bool argument by adding an extra if statement at the call
site, and repurposes the no_auto_back_and_forth variable to
auto_back_and_forth for simpler understanding.
|
|
This forces no_auto_back_and_forth to true for `workspace
next_on_output` and `workspace prev_on_output` to keep parity with i3.
In i3, running next_on_output never changes focus to another output.
In Sway currently, with workspace_auto_back_and_forth set to yet,
running next_on_output on an output with only a single active workspace
will typically end up focussing the other output:
1. next_on_output focusses the current workspace, because it's the only
one
2. auto_back_and_forth focusses the last focussed workspace, because the
current workspace to focus is the current one. This will usually be on
the other monitor if the workspace there was last focussed.
|
|
Uses --layer/-y set to overlay|top|bottom|background
|
|
|
|
Sway ignores SIGPIPE (by installing a SIG_IGN handler), in order to
“prevent IPC from crashing Sway”.
SIG_IGN handlers are the *only* signal handlers inherited in
sub-processes. As such, we should be a good citizen and restore the
SIGPIPE handler to its default handler.
Original bug report:
https://www.mail-archive.com/debian-bugs-dist@lists.debian.org/msg1806907.html
|
|
Sway ignores SIGPIPE (by installing a SIG_IGN handler), in order to
“prevent IPC from crashing Sway”.
SIG_IGN handlers are the *only* signal handlers inherited in
sub-processes. As such, we should be a good citizen and restore
the SIGPIPE handler to its default handler.
Original bug report:
https://www.mail-archive.com/debian-bugs-dist@lists.debian.org/msg1806907.html
|
|
Until now, swaybar did not have pango markup enabled by default, even if
the sway config had it on. This patch aims to mimic the i3 behavior, but
maintaining the functionality of the "pango_markup" sway config command.
|
|
Deferred commands are only run once, during sway startup. This means
that deferring seat attachment based on whether we are reading the
config prevents devices from being reattached to the correct seat during
a config reload. Instead, only defer if the config is not yet active.
Fixes #6048.
|
|
Update for the breaking change in [1].
[1]: https://github.com/swaywm/wlroots/pull/2948
|
|
See https://github.com/swaywm/wlroots/pull/2718.
|
|
|
|
|
|
Change the webchat links from freenode.net to point to the new
destination libera.chat.
Co-authored-by: Simon Ser <contact@emersion.fr>
|
|
|
|
update for wlroots 6369f7093178f0d66414eb67c312a403bfbb84a4
|
|
|
|
|
|
|